| Specification | Rated current In(A) | The adjusting rage of commuting current | The cutting capacity for rated limit short circuit lcu,the cutting capacity for rated work short circuit lcs | The distance of arcs(mm) | |||||||||
| 230/240V | 400/415V | 440V | 500V | 690V | |||||||||
| Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | ||||
| GV2ME01C | 0.16 | 0.10-0.16 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2ME02C | 0.25 | 0.16-0.25 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2ME03C | 0.4 | 0.25-0.40 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2ME04C | 0.63 | 0.40-0.63 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2ME05C | 1 | 0.63-1.00 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2ME06C | 1.6 | 1.00-1.60 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2ME07C | 2.5 | 1.60-2.50 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 |
| GV2ME08C | 4 | 2.50-4.00 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 |
| GV2ME10C | 6.3 | 4.00-6.30 | 100 | 100 | 100 | 100 | 50 | 50 | 50 | 50 | 3 | 2.25 | 40 |
| GV2ME14C | 10 | 6.00-10.00 | 100 | 100 | 100 | 100 | 15 | 15 | 10 | 10 | 3 | 2.25 | 40 |
| GV2ME18C | 14 | 9.00-14.00 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 |
| GV2ME20C | 18 | 13.00-18.00 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 |
| GV2ME21C | 23 | 17.00-23.00 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
| GV2ME22C | 25 | 20.00-25.00 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
| GV2ME32C | 32 | 24.00-32.00 | 50 | 50 | 10 | 5 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
| The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
| The multiple of rated current | Starting state | Stipulated time | Due result | The temperature of ambient air | |||||
| 1.05 | Cold state | t≤2h | No disjounting | +40℃±2℃ | |||||
| 1.2 | Hot state (rises up to the stipulated currentafter following the test of No 1) | t< 2h | Disjounting | ||||||
| 1.5 | One-time commuting curren Starts after the bot balance | t< 2min | Disjounting | ||||||
| 7.2 | Cold state | 2<t≤10s | Disjounting | ||||||
| The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
| The multiple of rated current | Starting state | Stipulated time | Due result | The temperature ofambient air | |||||
| Any two phases | The third phases | ||||||||
| 1 | 0.9 | Cold state | t≤2h | No disjounting | +40℃±2℃ | ||||
| 1.15 | 0 | Hot state (rises up to the stipulatedcurrent after following the test of No 1) | t< 2h | Disjounting | |||||
| Other parameters | |||||||||
| Ratedinsulation voltage Ui(V):690; | |||||||||
| Rated work voltage Ue(V):230/240、400/415、440、550、690; | |||||||||
| Rated frequency Hz:50/60; | |||||||||
| The grade rated current ofshell Inm(A):32; | |||||||||
| The bearable voltage forrated shock Uimp(V):8000。 | |||||||||
















Here is a revised version of the product details for the GV2-ME Motor Circuit Breaker, ensuring that relevant keywords are used at least five times and pronouns are replaced with specific terms: The GV2-ME Motor Circuit Breaker is a reliable solution designed specifically for motor protection. The GV2-ME Motor Circuit Breaker ensures thermal-magnetic protection, safeguarding motors from overloads and short circuits. With its compact design, the GV2-ME Motor Circuit Breaker is ideal for use in industrial and commercial applications where space and efficiency are critical.
The GV2-ME Motor Circuit Breaker offers both manual and automatic reset options, making it versatile for various motor control setups. Additionally, the GV2-ME Motor Circuit Breaker provides adjustable current settings to match the specific requirements of different motor types, ensuring optimal performance and safety.
Installation of the GV2-ME Motor Circuit Breaker is straightforward, thanks to its user-friendly design and compatibility with a wide range of electrical systems. The GV2-ME Motor Circuit Breaker can be easily integrated into existing motor control panels, providing enhanced protection without the need for extensive modifications.
By choosing the GV2-ME Motor Circuit Breaker, users benefit from a durable and efficient solution that extends motor lifespan while reducing downtime due to electrical faults. The GV2-ME Motor Circuit Breaker is an essential component for any system requiring reliable motor protection.













