Specification | Rated current In(A) | The adjusting rage of commuting current | The cutting capacity for rated limit short circuit lcu,the cutting capacity for rated work short circuit lcs | The distance of arcs(mm) | |||||||||
230/240V | 400/415V | 440V | 500V | 690V | |||||||||
Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | ||||
GV2ME01C | 0.16 | 0.10-0.16 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
GV2ME02C | 0.25 | 0.16-0.25 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
GV2ME03C | 0.4 | 0.25-0.40 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
GV2ME04C | 0.63 | 0.40-0.63 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
GV2ME05C | 1 | 0.63-1.00 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
GV2ME06C | 1.6 | 1.00-1.60 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
GV2ME07C | 2.5 | 1.60-2.50 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 |
GV2ME08C | 4 | 2.50-4.00 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 |
GV2ME10C | 6.3 | 4.00-6.30 | 100 | 100 | 100 | 100 | 50 | 50 | 50 | 50 | 3 | 2.25 | 40 |
GV2ME14C | 10 | 6.00-10.00 | 100 | 100 | 100 | 100 | 15 | 15 | 10 | 10 | 3 | 2.25 | 40 |
GV2ME18C | 14 | 9.00-14.00 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 |
GV2ME20C | 18 | 13.00-18.00 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 |
GV2ME21C | 23 | 17.00-23.00 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
GV2ME22C | 25 | 20.00-25.00 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
GV2ME32C | 32 | 24.00-32.00 | 50 | 50 | 10 | 5 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
The multiple of rated current | Starting state | Stipulated time | Due result | The temperature of ambient air | |||||
1.05 | Cold state | t≤2h | No disjounting | +40℃±2℃ | |||||
1.2 | Hot state (rises up to the stipulated currentafter following the test of No 1) | t< 2h | Disjounting | ||||||
1.5 | One-time commuting curren Starts after the bot balance |
t< 2min | Disjounting | ||||||
7.2 | Cold state | 2<t≤10s | Disjounting |
The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
The multiple of rated current | Starting state | Stipulated time | Due result | The temperature ofambient air | |||||
Any two phases | The third phases | ||||||||
1 | 0.9 | Cold state | t≤2h | No disjounting | +40℃±2℃ | ||||
1.15 | 0 | Hot state (rises up to the stipulatedcurrent after following the test of No 1) | t< 2h | Disjounting | |||||
Other parameters | |||||||||
Ratedinsulation voltage Ui(V):690; | |||||||||
Rated work voltage Ue(V):230/240、400/415、440、550、690; | |||||||||
Rated frequency Hz:50/60; | |||||||||
The grade rated current ofshell Inm(A):32; | |||||||||
The bearable voltage forrated shock Uimp(V):8000。 |
Here is a revised version of the product details for the GV2-ME Motor Circuit Breaker, ensuring that relevant keywords are used at least five times and pronouns are replaced with specific terms: The GV2-ME Motor Circuit Breaker is a reliable solution designed specifically for motor protection. The GV2-ME Motor Circuit Breaker ensures thermal-magnetic protection, safeguarding motors from overloads and short circuits. With its compact design, the GV2-ME Motor Circuit Breaker is ideal for use in industrial and commercial applications where space and efficiency are critical.
The GV2-ME Motor Circuit Breaker offers both manual and automatic reset options, making it versatile for various motor control setups. Additionally, the GV2-ME Motor Circuit Breaker provides adjustable current settings to match the specific requirements of different motor types, ensuring optimal performance and safety.
Installation of the GV2-ME Motor Circuit Breaker is straightforward, thanks to its user-friendly design and compatibility with a wide range of electrical systems. The GV2-ME Motor Circuit Breaker can be easily integrated into existing motor control panels, providing enhanced protection without the need for extensive modifications.
By choosing the GV2-ME Motor Circuit Breaker, users benefit from a durable and efficient solution that extends motor lifespan while reducing downtime due to electrical faults. The GV2-ME Motor Circuit Breaker is an essential component for any system requiring reliable motor protection.
The GV2-ME provides thermal-magnetic protection for motors, safeguarding against both short circuits and overloads without needing an external thermal relay.
The GV2-ME offers both short circuit and overload protection, while the GV2LE only provides short circuit protection and requires an external thermal relay for overload protection.
Yes, the GV2-ME can be used on a single-phase network by connecting two of its poles in series.
The short circuit withstand rating (Isc) varies depending on the specific model and application. Always refer to product specifications for precise values.