Specification | In(A) Rated current In(A) |
The adjusting rage of commuting current | The cutting capacity for rated limit short circuit lcu,the cutting capacity for rated work short circuit lcs | The distance of arcs(mm) | |||||
230/240V | 400/415V | 690V | |||||||
Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | ||||
GV3M10 | 10A | 6-10A | / | / | 15 | 7.5 | 4 | 2 | 50 |
GV3M16 | 16A | 10-16A | 15 | 7.5 | 4 | 2 | 50 | ||
GV3M20 | 20A | 14-20A | 15 | 7.5 | 4 | 2 | 50 | ||
GV3M25 | 25A | 16-25A | 15 | 7.5 | 4 | 2 | 50 | ||
GV3M40 | 40A | 25-40A | 15 | 7.5 | 4 | 2 | 50 | ||
GV3M63 | 63A | 40-63A | 15 | 7.5 | 4 | 2 | 50 | ||
GV3M80 | 80A | 56-80A | 15 | 7.5 | 4 | 2 | 50 |
The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
The multiple of rated current | Starting state | Stipulated time | Due result | The temperature of ambient air | |||||
1.05 | Cold state | t≥2h | No disjounting | +20℃±2℃ | |||||
1.3 | Hot state (rises up to the stipulated currentafter following the test of No 1) | t< 2h | Disjounting | ||||||
10 | Cold state | t< 2s | Disjounting |
The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
The multiple of rated current | Starting state | Stipulated time | Due result | The temperature ofambient air | |||||
Any two phases | The third phases | ||||||||
1 | 0.9 | Cold state | t≤2h | No disjounting | +40℃±2℃ | ||||
1.15 | 0 | Hot state (rises up to the stipulatedcurrent after following the test of No 1) | t< 2h | Disjounting |
Here is a revised version of the product details for the GV3-M10 6-10A Motor Protection Circuit Breaker (MPCB), ensuring that relevant keywords are used at least five times and pronouns are replaced with specific terms: The GV3-M10 6-10A Motor Protection Circuit Breaker (MPCB) is designed to provide reliable protection for motors operating within the 6 to 10 amp range. The GV3-M10 Motor Protection Circuit Breaker offers both thermal and magnetic protection, ensuring that motors are safeguarded from overloads and short circuits. By using the GV3-M10 MPCB, users can enhance motor performance and extend the lifespan of their equipment.
One of the key features of the GV3-M10 6-10A Motor Protection Circuit Breaker is its adjustable trip settings, which allow for precise customization based on motor requirements. This makes the GV3-M10 Motor Protection Circuit Breaker suitable for a wide range of applications, including industrial machinery, pumps, compressors, and other equipment operating within this current range. The GV3-M10 MPCB ensures that motors are protected without unnecessary interruptions in operation.
The compact design of the GV3-M10 6-10A Motor Protection Circuit Breaker allows for easy installation in existing motor control panels. The GV3-M10 Motor Protection Circuit Breaker is compatible with both single-phase and three-phase systems, providing flexibility for various motor configurations. Whether used in industrial or commercial settings, the GV3-M10 MPCB delivers reliable protection for medium-sized motors.
In addition to protecting motors from overloads and short circuits, the GV3-M10 6-10A Motor Protection Circuit Breaker also helps reduce maintenance costs by preventing motor damage due to electrical faults. The durable construction of the GV3-M10 Motor Protection Circuit Breaker ensures long-term performance even in demanding environments. This makes the GV3-M10 MPCB an essential component in any motor control system requiring dependable protection.
By choosing the GV3-M10 6-10A Motor Protection Circuit Breaker, users can ensure that their motors are protected from electrical faults while maintaining efficient operation. The GV3-M10 MPCB not only enhances safety but also improves overall system reliability by minimizing downtime caused by electrical issues. For any application requiring motor protection within this current range, the GV3-M10 Motor Protection Circuit Breaker is a highly effective solution.
The GV3-M10 MPCB is designed for motors with a current rating range of 6 to 10 amps, providing reliable protection for medium-sized motors in various applications.
The GV3-M10 MPCB offers both thermal and magnetic protection, safeguarding motors from overloads and short circuits, ensuring long-term motor reliability.
Yes, the GV3-M10 MPCB is compatible with three-phase systems, making it suitable for industrial and commercial motor protection applications.
The GV3-M10 MPCB is ideal for protecting motors in industrial machinery, pumps, compressors, and other equipment that operates within the 6-10A current range.
Yes, the compact design of the GV3-M10 MPCB allows for easy installation in existing motor control panels, providing quick and efficient motor protection without requiring additional components.
We value your privacy
We use cookies to enhance your browsing experience, serve personalised ads or content, and analyse our traffic. By clicking "Accept All", you consent to our use of cookies.
Our products are trusted for their superior quality and reliability. Fill out the form and we will answer any questions you may have.
We take your privacy very seriously. Please rest assured that the email address you provide will only be used to contact you or send relevant information, and we will never disclose your email address to a third party. The security of your information is our top priority. Privacy Policy