Product Overview
This manual starter and protector is designed for motor starting, switching, and protection in industrial control systems. With dependable thermal magnetic protection, it is suitable for 3 phase motor applications that require compact structure, reliable manual operation, and stable overload and short-circuit protection.
It is widely used in motor control panels, machinery, pumps, compressors, and automation systems where safe motor switching and reliable protection are required.
Key Features
• Manual starter and protector for industrial motor control
• Suitable for 3 phase motor protection applications
• Thermal magnetic protection against overload and short circuit
• Compact design for panel installation and maintenance
• Reliable manual switching and motor control
• Suitable for motor control panels and automation systems
• Reliable performance for OEM, distributor, and project orders


Technical Specifications of Manual Starter and Protector
Below are the main technical details of this manual starter and protector. For detailed drawings, configuration support, or OEM requirements, please contact us directly.
| Product Name | Manual Starter and Protector |
|---|---|
| Series / Model | GV2-M |
| Product Type | Thermal Magnetic Motor Circuit Breaker |
| Application | 3 Phase Motor Protection |
| Protection Function | Overload and Short-Circuit Protection |
| Operation | Manual Switching and Motor Control |
| Installation | DIN Rail / Panel Mounting |
| Usage | Motor Starting, Switching, and Protection |
| Application Field | Motor Control Panels, Machinery, Pumps, Compressors |
| OEM / ODM Service | Available |
| Specification | Rated current In(A) | The adjusting rage of commuting current | The cutting capacity for rated limit short circuit lcu,the cutting capacity for rated work short circuit lcs | The distance of arcs(mm) | |||||||||
| 230/240V | 400/415V | 440V | 500V | 690V | |||||||||
| Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | Icu(KA) | Ics(KA) | ||||
| GV2M01C | 0.16 | 0.10-0.16 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2M02C | 0.25 | 0.16-0.25 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2M03C | 0.4 | 0.25-0.40 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2M04C | 0.63 | 0.40-0.63 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2M05C | 1 | 0.63-1.00 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2M06C | 1.6 | 1.00-1.60 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 40 |
| GV2M07C | 2.5 | 1.60-2.50 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 |
| GV2M08C | 4 | 2.50-4.00 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | 3 | 2.25 | 40 |
| GV2M10C | 6.3 | 4.00-6.30 | 100 | 100 | 100 | 100 | 50 | 50 | 50 | 50 | 3 | 2.25 | 40 |
| GV2M14C | 10 | 6.00-10.00 | 100 | 100 | 100 | 100 | 15 | 15 | 10 | 10 | 3 | 2.25 | 40 |
| GV2M18C | 14 | 9.00-14.00 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 |
| GV2M20C | 18 | 13.00-18.00 | 100 | 100 | 15 | 7.5 | 8 | 4 | 6 | 4.5 | 3 | 2.25 | 40 |
| GV2M21C | 23 | 17.00-23.00 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
| GV2M22C | 25 | 20.00-25.00 | 50 | 50 | 15 | 6 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
| GV2M32C | 32 | 24.00-32.00 | 50 | 50 | 10 | 5 | 6 | 3 | 4 | 3 | 3 | 2.25 | 40 |
| he action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
| The multiple of rated current | Starting state | Stipulated time | Due result | The temperature of ambient air | |||||
| 1.05 | Cold state | t≤2h | No disjounting | +40℃±2℃ | |||||
| 1.2 | Hot state (rises up to the stipulated currentafter following the test of No 1) | t< 2h | Disjounting | ||||||
| 1.5 | One-time commuting curren Starts after the bot balance | t< 2min | Disjounting | ||||||
| 7.2 | Cold state | 2<t≤10s | Disjounting | ||||||
| The action characteristic of breaker(GV2 Motor circuit breaker) when every phase load is in balance | |||||||||
| The multiple of rated current | Starting state | Stipulated time | Due result | The temperature ofambient air | |||||
| Any two phases | The third phases | ||||||||
| 1 | 0.9 | Cold state | t≤2h | No disjounting | +40℃±2℃ | ||||
| 1.15 | 0 | Hot state (rises up to the stipulatedcurrent after following the test of No 1) | t< 2h | Disjounting | |||||
| Other parameters | |||||||||
| Ratedinsulation voltage Ui(V):690; | |||||||||
| Rated work voltage Ue(V):230/240、400/415、440、550、690; | |||||||||
| Rated frequency Hz:50/60; | |||||||||
| The grade rated current ofshell Inm(A):32; | |||||||||
| The bearable voltage forrated shock Uimp(V):8000。 | |||||||||
Applications
This manual starter and protector is suitable for a wide range of industrial applications, including:
• Motor control panels
• Pumps and water systems
• Air compressors
• Industrial machinery
• HVAC equipment
• Conveyors
• Industrial automation systems
• Power distribution and equipment protection projects


Why Choose Our Manual Starter and Protector
Our manual starter and protector is designed for dependable motor protection and convenient manual operation in industrial environments. We support OEM and private label service for distributors, wholesalers, panel builders, and project buyers. With factory-direct supply and responsive quotation service, we help customers improve sourcing efficiency and control purchasing cost.
Looking for a reliable manual starter and protector manufacturer or supplier? Contact us today for pricing, OEM support, technical details, and bulk order information.








FAQ
What is a manual starter and protector?
A manual starter and protector is a compact device used for motor starting, switching, and protection. It combines manual motor control with overload and short-circuit protection for industrial motor applications.
Is this product suitable for 3 phase motors?
Yes. This manual starter and protector is suitable for 3 phase motor protection and is commonly used in industrial control panels and machinery systems.
What protection functions does this product provide?
It provides thermal magnetic protection, including overload protection and short-circuit protection for motor circuits.
Can you provide OEM or private label service?
Yes. We support OEM and private label service for distributors, wholesalers, and project customers.
Where is this product commonly used?
It is commonly used in pumps, compressors, HVAC systems, industrial machinery, automation systems, and motor control cabinets.
Request a Quote Now
Our team will get back to you within 24 hours.